TY - JOUR
T1 - Determination of N-desmethyl- and N-bisdesmethyl metabolites of Sibutramine in doping control analysis using liquid chromatography-tandem mass spectrometry
AU - Thevis, Mario
AU - Sigmund, Gerd
AU - Schiffer, Anna-Katharina
AU - Schänzer, Wilhelm
PY - 2006/1/1
Y1 - 2006/1/1
N2 - Since January 2006, the list of prohibited substances established by the World Anti-Doping Agency includes the antidepressant / anti-obesity drug Sibutramine. Due to its rapid degradation to its active metabolites N-desmethyl and N-bisdesmethyl Sibutramine, reference compounds were synthesized and included into an existing screening assay to allow the unambiguous determination of these metabolic products in human urine using liquid-liquid extraction followed by liquid chromatography/tandem mass spectrometry. Characteristic product ions, obtained after electrospray ionization and collision-induced dissociation, were elucidated using high resolution/high accuracy mass measurements with a hybrid linear ion trap/orbitrap mass analyzer. Based on diagnostic product ions, the extended screening procedure was validated for both Sibutramine metabolites using a triple quadrupole mass spectrometer. Items such as lower limits of detection (6-40 ng mL(-1)), recoveries (39-42%), intraday precision (low: 5.5-10.6%, medium: 4.9-5.9%), high: 12.8-16.4%) and interday precision (low: 15.0-22.8%, medium: 17.7-18.6%), high: 16.5-25.6%) were evaluated, and a clinical spot urine sample was analyzed to demonstrate the applicability of the developed assay in sports drug testing.
AB - Since January 2006, the list of prohibited substances established by the World Anti-Doping Agency includes the antidepressant / anti-obesity drug Sibutramine. Due to its rapid degradation to its active metabolites N-desmethyl and N-bisdesmethyl Sibutramine, reference compounds were synthesized and included into an existing screening assay to allow the unambiguous determination of these metabolic products in human urine using liquid-liquid extraction followed by liquid chromatography/tandem mass spectrometry. Characteristic product ions, obtained after electrospray ionization and collision-induced dissociation, were elucidated using high resolution/high accuracy mass measurements with a hybrid linear ion trap/orbitrap mass analyzer. Based on diagnostic product ions, the extended screening procedure was validated for both Sibutramine metabolites using a triple quadrupole mass spectrometer. Items such as lower limits of detection (6-40 ng mL(-1)), recoveries (39-42%), intraday precision (low: 5.5-10.6%, medium: 4.9-5.9%), high: 12.8-16.4%) and interday precision (low: 15.0-22.8%, medium: 17.7-18.6%), high: 16.5-25.6%) were evaluated, and a clinical spot urine sample was analyzed to demonstrate the applicability of the developed assay in sports drug testing.
KW - Chromatography, Liquid
KW - Cyclobutanes
KW - Doping in Sports
KW - Female
KW - Humans
KW - Middle Aged
KW - Spectrometry, Mass, Electrospray Ionization
KW - Tandem Mass Spectrometry
U2 - 10.1255/ejms.797
DO - 10.1255/ejms.797
M3 - Journal articles
C2 - 16723754
SN - 1469-0667
VL - 12
SP - 129
EP - 136
JO - European journal of mass spectrometry (Chichester, England)
JF - European journal of mass spectrometry (Chichester, England)
IS - 2
ER -