TY - JOUR
T1 - Doping control analysis of trenbolone and related compounds using liquid chromatography-tandem mass spectrometry
AU - Thevis, Mario
AU - Guddat, Sven
AU - Schänzer, Wilhelm
PY - 2009/3/1
Y1 - 2009/3/1
N2 - Trenbolone (17beta-hydroxy-estra-4,9,11-trien-3-one) and its derivatives such as 17alpha-methyltrenbolone represent a class of highly potent anabolic-androgenic steroids, which are prohibited in sports according to the regulation of the World Anti-Doping Agency (WADA). Due to marginal gas chromatographic properties of these compounds but excellent proton affinities resulting from a large and conjugated pi-electron system, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been the method of choice for the detection of these analytes in sports drug testing. Recent findings of trenbolone and methyltrenbolone in doping control urine samples of elite athletes demonstrated the importance of a sensitive and robust analytical method, which was based on an enzymatic hydrolysis of target compounds, liquid-liquid extraction and subsequent LC-MS/MS measurement. Diagnostic product ions obtained after collision-induced dissociation of protonated molecules were found at m/z 227, 211, 199 and 198, which enabled targeted screening using multiple reaction monitoring. Using 7 model compounds (trenbolone, epitrenbolone, methyltrenbolone, ethyltrenbolone, propyltrenbolone, 17-ketotrenbolone and altrenogest), the established method was validated for specificity, lower limits of detection (0.3-3ng/mL), recovery (72-105%), intraday and interday precision (< or =20%).
AB - Trenbolone (17beta-hydroxy-estra-4,9,11-trien-3-one) and its derivatives such as 17alpha-methyltrenbolone represent a class of highly potent anabolic-androgenic steroids, which are prohibited in sports according to the regulation of the World Anti-Doping Agency (WADA). Due to marginal gas chromatographic properties of these compounds but excellent proton affinities resulting from a large and conjugated pi-electron system, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been the method of choice for the detection of these analytes in sports drug testing. Recent findings of trenbolone and methyltrenbolone in doping control urine samples of elite athletes demonstrated the importance of a sensitive and robust analytical method, which was based on an enzymatic hydrolysis of target compounds, liquid-liquid extraction and subsequent LC-MS/MS measurement. Diagnostic product ions obtained after collision-induced dissociation of protonated molecules were found at m/z 227, 211, 199 and 198, which enabled targeted screening using multiple reaction monitoring. Using 7 model compounds (trenbolone, epitrenbolone, methyltrenbolone, ethyltrenbolone, propyltrenbolone, 17-ketotrenbolone and altrenogest), the established method was validated for specificity, lower limits of detection (0.3-3ng/mL), recovery (72-105%), intraday and interday precision (< or =20%).
KW - Chromatography, Liquid
KW - Doping in Sports
KW - Humans
KW - Molecular Structure
KW - Reproducibility of Results
KW - Substance Abuse Detection
KW - Tandem Mass Spectrometry
KW - Trenbolone Acetate
U2 - 10.1016/j.steroids.2008.10.004
DO - 10.1016/j.steroids.2008.10.004
M3 - Journal articles
C2 - 19007801
SN - 0039-128X
VL - 74
SP - 315
EP - 321
JO - Steroids
JF - Steroids
IS - 3
ER -