TY - JOUR
T1 - Expanding analytical possibilities concerning the detection of stanozolol misuse by means of high resolution/high accuracy mass spectrometric detection of stanozolol glucuronides in human sports drug testing
AU - Schänzer, Wilhelm
AU - Guddat, Sven
AU - Thomas, Andreas
AU - Opfermann, Georg
AU - Geyer, Hans
AU - Thevis, Mario
N1 - Copyright © 2013 John Wiley & Sons, Ltd.
PY - 2013
Y1 - 2013
N2 - Anabolic-androgenic steroids (AAS) represent one of the most frequently detected classes of prohibited substances in doping controls. Due to their long-lasting beneficial effects on athletic performance, utmost retrospectivity via urine analysis is desirable and accomplished by targeting long-term metabolites of the respective drugs. In case of stanozolol, a substantial variety of metabolites has enabled the identification of numerous adverse analytical findings in the past, and recent studies concerning complementary phase-I and phase-II metabolites has further expanded the windows of opportunity for detecting the abuse of stanozolol. In this study, the utility of liquid chromatography-high resolution/high accuracy (tandem) mass spectrometry (LC-MS/MS) for the detection of 3'-OH-stanozolol glucuronide in sports drug testing is presented and the identification of two additional and so far unreported metabolites is shown. The structures of the complementary glucuronic acid conjugates were attributed to stanozolol-N-glucuronide and 17-epistanozolol-N-glucuronide. By means of chemical synthesis, stanozolol-N-glucuronide was prepared and used to corroborate the suggested structures. The 3'-OH-stanozolol glucuronide and the newly identified target compounds were implemented into routine sports drug test assays consisting of direct injection LC-MS/MS or solid-phase extraction (SPE) followed by LC-MS/MS. A considerably expanded detection window for stanozolol abuse was demonstrated compared to the use of conventional phase-I metabolites and methodologies based on, for example, low resolution LC-MS/MS or gas chromatography-tandem mass spectrometry (GC-MS/MS). The commercial availability of 3'-OH-stanozolol glucuronide has been of great value for confirmatory purposes, and 17-epistanozolol-N-glucuronide was found to be a favourable long-term metabolite for doping controls as it was observed up to 28 days post-administration of the drug. Applying the established methodology over a period of six months to 659 routine sports drug testing samples, a total of 85 adverse analytical findings was uncovered, 72 of which would have remained undetected using earlier employed GC-MS/MS approaches.
AB - Anabolic-androgenic steroids (AAS) represent one of the most frequently detected classes of prohibited substances in doping controls. Due to their long-lasting beneficial effects on athletic performance, utmost retrospectivity via urine analysis is desirable and accomplished by targeting long-term metabolites of the respective drugs. In case of stanozolol, a substantial variety of metabolites has enabled the identification of numerous adverse analytical findings in the past, and recent studies concerning complementary phase-I and phase-II metabolites has further expanded the windows of opportunity for detecting the abuse of stanozolol. In this study, the utility of liquid chromatography-high resolution/high accuracy (tandem) mass spectrometry (LC-MS/MS) for the detection of 3'-OH-stanozolol glucuronide in sports drug testing is presented and the identification of two additional and so far unreported metabolites is shown. The structures of the complementary glucuronic acid conjugates were attributed to stanozolol-N-glucuronide and 17-epistanozolol-N-glucuronide. By means of chemical synthesis, stanozolol-N-glucuronide was prepared and used to corroborate the suggested structures. The 3'-OH-stanozolol glucuronide and the newly identified target compounds were implemented into routine sports drug test assays consisting of direct injection LC-MS/MS or solid-phase extraction (SPE) followed by LC-MS/MS. A considerably expanded detection window for stanozolol abuse was demonstrated compared to the use of conventional phase-I metabolites and methodologies based on, for example, low resolution LC-MS/MS or gas chromatography-tandem mass spectrometry (GC-MS/MS). The commercial availability of 3'-OH-stanozolol glucuronide has been of great value for confirmatory purposes, and 17-epistanozolol-N-glucuronide was found to be a favourable long-term metabolite for doping controls as it was observed up to 28 days post-administration of the drug. Applying the established methodology over a period of six months to 659 routine sports drug testing samples, a total of 85 adverse analytical findings was uncovered, 72 of which would have remained undetected using earlier employed GC-MS/MS approaches.
UR - https://www.scopus.com/pages/publications/84890790026
U2 - 10.1002/dta.1516
DO - 10.1002/dta.1516
M3 - Journal articles
C2 - 23873860
SN - 1942-7611
VL - 5
SP - 810
EP - 818
JO - Drug testing and analysis
JF - Drug testing and analysis
IS - 11-12
ER -