TY - JOUR
T1 - Polyamines, myosin heavy chains, and collagen specific amino acids after a repeated bout of eccentric exercise
AU - Behringer, Michael
AU - Montag, Johannes Caspar Konrad
AU - Kilian, Yvonne
AU - Heaton, Phil
AU - Mester, Joachim
PY - 2016/7/6
Y1 - 2016/7/6
N2 - We investigated alternatives to commonly used biomarkers of exercise-induced tissue damage. Over 5 days following two bouts of 100 drop-to-vertical jumps (inter-bout rest period of 3 weeks), myosin heavy chain 1, hydroxylysine (HYL), hydroxyproline (HYP), spermine (SPM) and spermine synthase (SMS) were measured in the serum of 10 participants. HYL significantly increased from 5.92 ± 1.49 ng/mL to 6.48 ± 1.47 ng/mL at 24 h. A similar trend was observed for bout 2, but without reaching significance. SPM significantly increased only after bout 1 from 0.96 ± 0.19 ng/mL at pretest to a peak level of 1.12 ± 0.26 ng/mL at 24 h, while B2 increments remained non-significant. Myosin heavy chain 1, HYP and SMS values remained below the detection limit of the applied enzyme-linked immunosorbent assay (ELISA) kit. Though HYL and SM increased after the intervention, both markers showed a large standard deviation (SD) combined with small increments. Therefore, none of the investigated biomarkers provides a meaningful alternative to commonly used damage markers.
AB - We investigated alternatives to commonly used biomarkers of exercise-induced tissue damage. Over 5 days following two bouts of 100 drop-to-vertical jumps (inter-bout rest period of 3 weeks), myosin heavy chain 1, hydroxylysine (HYL), hydroxyproline (HYP), spermine (SPM) and spermine synthase (SMS) were measured in the serum of 10 participants. HYL significantly increased from 5.92 ± 1.49 ng/mL to 6.48 ± 1.47 ng/mL at 24 h. A similar trend was observed for bout 2, but without reaching significance. SPM significantly increased only after bout 1 from 0.96 ± 0.19 ng/mL at pretest to a peak level of 1.12 ± 0.26 ng/mL at 24 h, while B2 increments remained non-significant. Myosin heavy chain 1, HYP and SMS values remained below the detection limit of the applied enzyme-linked immunosorbent assay (ELISA) kit. Though HYL and SM increased after the intervention, both markers showed a large standard deviation (SD) combined with small increments. Therefore, none of the investigated biomarkers provides a meaningful alternative to commonly used damage markers.
KW - Journal Article
U2 - 10.1080/15438627.2016.1202830
DO - 10.1080/15438627.2016.1202830
M3 - Journal articles
C2 - 27379471
SN - 1543-8627
VL - 24
SP - 272
EP - 282
JO - Research in Sports Medicine
JF - Research in Sports Medicine
IS - 3
ER -