TY - JOUR
T1 - Prognostic Value of Peak Oxygen Uptake in Patients Supported With Left Ventricular Assist Devices (PRO-VAD)
AU - Mirza, Kiran K
AU - Szymanski, Mariusz K
AU - Schmidt, Thomas
AU - de Jonge, Nicolaas
AU - Brahmbhatt, Darshan H
AU - Billia, Filio
AU - Hsu, Steven
AU - MacGowan, Guy A
AU - Jakovljevic, Djordje G
AU - Agostoni, Piergiuseppe
AU - Trombara, Filippo
AU - Jorde, Ulrich
AU - Rochlani, Yogita
AU - Vandersmissen, Katrien
AU - Reiss, Nils
AU - Russell, Stuart D
AU - Meyns, Bart
AU - Gustafsson, Finn
N1 - Copyright © 2021 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
PY - 2021/10
Y1 - 2021/10
N2 - OBJECTIVES: The purpose of this study was to examine whether peak oxygen uptake (pVO2) and other cardiopulmonary exercise test (CPET)-derived variables could predict intermediate-term mortality in stable continuous flow LVAD recipients.BACKGROUND: pVO2 is a cornerstone in the selection of patients for heart transplantation, but the prognostic power of pVO2 obtained in patients treated with a left ventricular assist device (LVAD) is unknown.METHODS: We collected data for pVO2 and outcomes in adult LVAD recipients in a retrospective, multicenter study and evaluated cutoff values for pVO2 including: 1) values above or below medians; 2) grouping patients in tertiles; and 3) pVO2 ≤14 ml/kg/min if the patient was not treated with beta-blockers (BB) or pVO2 ≤12 ml/kg/min if the patient was taking BB therapy.RESULTS: Nine centers contributed data from 450 patients. Patients were 53 ± 13 years of age; 78% were male; body mass index was 25 ± 5 kg/m2 with few comorbidities (stroke: 11%; diabetes: 18%; and peripheral artery disease: 4%). The cause of heart failure (HF) was most often nonischemic (66%). Devices included were the HeartMate II and 3 (Abbott); and Heartware ventricular assist devices Jarvik and Duraheart (Medtronic). The index CPET was performed at a median of 189 days (154-225 days) after LVAD implantation, and mean pVO2 was 14.1 ± 5 ml/kg/min (47% ± 14% of predicted value). Lower pVO2 values were strongly associated with poorer survival regardless of whether patients were analyzed for absolute pVO2 in ml/kg/min, pVO2 ≤12 BB/14 ml/kg/min, or as a percentage of predicted pVO2 values (P ≤ 0.001 for all). For patients with pVO2 >12 BB/14 and ventilation/carbon dioxide relationship (VE/VCO2) slope <35, the 1-year survival was 100%.CONCLUSIONS: Even after LVAD implantation, pVO2 has prognostic value, similar to HF patients not supported by mechanical circulatory support devices. (PROgnostic Value of Exercise Capacity Measured as Peak Oxygen Uptake [pVO2] in Recipients of Left Ventricular Assist Devices [PRO-VAD]; NCT04423562).
AB - OBJECTIVES: The purpose of this study was to examine whether peak oxygen uptake (pVO2) and other cardiopulmonary exercise test (CPET)-derived variables could predict intermediate-term mortality in stable continuous flow LVAD recipients.BACKGROUND: pVO2 is a cornerstone in the selection of patients for heart transplantation, but the prognostic power of pVO2 obtained in patients treated with a left ventricular assist device (LVAD) is unknown.METHODS: We collected data for pVO2 and outcomes in adult LVAD recipients in a retrospective, multicenter study and evaluated cutoff values for pVO2 including: 1) values above or below medians; 2) grouping patients in tertiles; and 3) pVO2 ≤14 ml/kg/min if the patient was not treated with beta-blockers (BB) or pVO2 ≤12 ml/kg/min if the patient was taking BB therapy.RESULTS: Nine centers contributed data from 450 patients. Patients were 53 ± 13 years of age; 78% were male; body mass index was 25 ± 5 kg/m2 with few comorbidities (stroke: 11%; diabetes: 18%; and peripheral artery disease: 4%). The cause of heart failure (HF) was most often nonischemic (66%). Devices included were the HeartMate II and 3 (Abbott); and Heartware ventricular assist devices Jarvik and Duraheart (Medtronic). The index CPET was performed at a median of 189 days (154-225 days) after LVAD implantation, and mean pVO2 was 14.1 ± 5 ml/kg/min (47% ± 14% of predicted value). Lower pVO2 values were strongly associated with poorer survival regardless of whether patients were analyzed for absolute pVO2 in ml/kg/min, pVO2 ≤12 BB/14 ml/kg/min, or as a percentage of predicted pVO2 values (P ≤ 0.001 for all). For patients with pVO2 >12 BB/14 and ventilation/carbon dioxide relationship (VE/VCO2) slope <35, the 1-year survival was 100%.CONCLUSIONS: Even after LVAD implantation, pVO2 has prognostic value, similar to HF patients not supported by mechanical circulatory support devices. (PROgnostic Value of Exercise Capacity Measured as Peak Oxygen Uptake [pVO2] in Recipients of Left Ventricular Assist Devices [PRO-VAD]; NCT04423562).
KW - Adult
KW - Exercise Test
KW - Heart Failure/therapy
KW - Heart-Assist Devices
KW - Humans
KW - Male
KW - Oxygen
KW - Oxygen Consumption
KW - Prognosis
KW - Retrospective Studies
U2 - 10.1016/j.jchf.2021.05.021
DO - 10.1016/j.jchf.2021.05.021
M3 - Journal articles
C2 - 34391745
SN - 2213-1779
VL - 9
SP - 758
EP - 767
JO - JACC. Heart failure
JF - JACC. Heart failure
IS - 10
ER -