TY - JOUR
T1 - Strain and elongation of the vastus lateralis aponeurosis and tendon in vivo during maximal isometric contraction
AU - Stafilidis, Savvas
AU - Karamanidis, Kiros
AU - Morey-Klapsing, Gaspar
AU - Demonte, Gianpiero
AU - Brüggemann, Gert-Peter
AU - Arampatzis, Adamantios
PY - 2005/6/1
Y1 - 2005/6/1
N2 - The strain and elongation of the vastus lateralis (VL) tendon, tendon plus aponeurosis, and aponeurosis were examined during maximal voluntary contractions on a Biodex-dynamometer (knee angle 115 degrees , hip angle 140 degrees ) in 12 sprinters. Following a warm-up phase, the subjects were instructed to perform a gradual maximal knee extension and hold it for about 3 s. The kinematics of the leg were recorded using a Vicon 512 system with eight cameras operating at 120 Hz. Ultrasonography images were taken simultaneously from the VL myotendinous junction and the mid lateral part of the VL muscle belly. During the maximal isometric knee extensions, the knee joint rotated (13.6+/-5.9 degrees ), leading to an overestimation of the elongation of the tendinous tissues. After correcting for this, the maximal elongation of the VL tendon examined at the myotendinous junction was lower (P<0.05) than the maximal elongation of the VL tendon plus aponeurosis examined at the muscle belly (15 vs. 27 mm, respectively). The maximal estimated strains of the tendon, tendon plus aponeurosis, and aponeurosis showed no statistical differences (8+/-2%, 8+/-1%, and 7+/-2%, respectively, P>0.05). It is concluded that the strains of the human VL tendon, VL tendon plus aponeurosis, and VL aponeurosis, as estimated in vivo by two dimensional ultrasound during maximal isometric contractions, do not differ from each other. The displacement measured at a cross point in the VL muscle belly is significantly greater than that measured at the VL myotendinous junction.
AB - The strain and elongation of the vastus lateralis (VL) tendon, tendon plus aponeurosis, and aponeurosis were examined during maximal voluntary contractions on a Biodex-dynamometer (knee angle 115 degrees , hip angle 140 degrees ) in 12 sprinters. Following a warm-up phase, the subjects were instructed to perform a gradual maximal knee extension and hold it for about 3 s. The kinematics of the leg were recorded using a Vicon 512 system with eight cameras operating at 120 Hz. Ultrasonography images were taken simultaneously from the VL myotendinous junction and the mid lateral part of the VL muscle belly. During the maximal isometric knee extensions, the knee joint rotated (13.6+/-5.9 degrees ), leading to an overestimation of the elongation of the tendinous tissues. After correcting for this, the maximal elongation of the VL tendon examined at the myotendinous junction was lower (P<0.05) than the maximal elongation of the VL tendon plus aponeurosis examined at the muscle belly (15 vs. 27 mm, respectively). The maximal estimated strains of the tendon, tendon plus aponeurosis, and aponeurosis showed no statistical differences (8+/-2%, 8+/-1%, and 7+/-2%, respectively, P>0.05). It is concluded that the strains of the human VL tendon, VL tendon plus aponeurosis, and VL aponeurosis, as estimated in vivo by two dimensional ultrasound during maximal isometric contractions, do not differ from each other. The displacement measured at a cross point in the VL muscle belly is significantly greater than that measured at the VL myotendinous junction.
KW - Adult
KW - Humans
KW - Isometric Contraction
KW - Knee Joint
KW - Leg
KW - Muscle, Skeletal
KW - Stress, Mechanical
KW - Tendons
U2 - 10.1007/s00421-004-1301-4
DO - 10.1007/s00421-004-1301-4
M3 - Journal articles
C2 - 15729551
SN - 1439-6319
VL - 94
SP - 317
EP - 322
JO - European journal of applied physiology
JF - European journal of applied physiology
IS - 3
ER -