Abstract

Manipulation of urine samples for drug testing or doping control analysis is a well-known problem, including dilution of urine, chemical adulteration or substitution by other liquids. Different analytical strategies have been developed to identify diluted or adulterated urine samples, as well as the identification of urine samples substituted with other liquids such as apple juice, alcohol-free beer, water or synthetic urine. Synthetic urine may contain different substances, including creatinine, uric acid and urea and show a specific gravity and pH similar to natural human urine samples. Several methods have been evolved within the last years to identify synthetic urine samples with routine analytical methods. These methods are based either on the identification of substance solely present in synthetic, but not natural urine, or on the identification of the absence of typically present urinary biomolecules.
In doping control analysis, the total absence of naturally occurring endogenous steroids (markers of the steroid profile) in a urine sample is strong evidence for a manipulated e.g. highly diluted or substituted sample. However, additional information supporting the assumption of a substitution of the original sample by synthetic urine can be particularly interesting.
A suspicious doping control urine sample without detectable amounts of endogenous steroids, a specific gravity of 1.014 and a pH of 8.3 revealed significant amounts of urea and protein. However, the nitrogen and carbon isotopic composition of urea and total urine indicated a synthetic origin, similar to commercially available urea standards and synthetic urine. The protein composition of the sample was investigated by SDS-PAGE and the pattern observed following Coomassie-staining was found to be rather unusual as only one intense band at an apparent MW of ~ 70 kDa and very few faint other signals were visible. In-gel tryptic digestion revealed the presence of bovine albumin instead of its human analog, clearly demonstrating a case of urine substitution.
Original languageEnglish
Title of host publicationRecent Advances in Doping Analysis (33) : Proceedings of the 43rd Cologne Workshop on Dope Analysis 2025
EditorsMario Thevis, Hans Geyer, Ute Mareck
Number of pages4
Volume33
Place of PublicationKöln
PublisherManfred Donike Institut für Dopinganalytik e.V. - Verlag
Publication date2025
Pages56-59
ISBN (Electronic)ISBN 978-3-9828334-0-8, https://doi.org/10.25847/mdi.2025.033
Publication statusPublished - 2025
EventManfred Donike Workshop: 43rd Cologne Workshop on Dope Analysis - Deutsche Sporthochschule Köln, Köln, Germany
Duration: 16.02.2025 → 20.02.2025

Fingerprint

Dive into the research topics of 'Detection of synthetic urea and bovine albumin in a specimen provided as human urine sample'. Together they form a unique fingerprint.

Citation