Skip to main navigation Skip to search Skip to main content

Implementation of volumetric absorptive microsampling technology (VAMS®) into sports nutrition – applications in research and practice

Publication: Contribution to journal › Conference abstract in journal › Research › peer-review

Abstract

In sports nutrition research and practice, collecting blood samples in the
field is challenging using venipuncture due to invasiveness and medical
staff needs. Microsampling techniques like VAMS® allow athletes to
collect capillary blood samples autonomously, enabling flexible sampling
for longitudinal studies and individualized measurements. Mitra® devices
with VAMS® technology consist of an absorbent polymeric tip on a plastic
holder, designed to acquire 30 μl blood from fingertips. Following
extraction, the samples underwent analysis using validated UHPLCHRMS/
MS methods. Direct comparisons of paired serum and VAMS®
samples (n=130) were performed to enhance the validity and accuracy of
the methods. Validated parameters include 25(OH)D2 and D3, 4-androstenedione,
cortisol, 17β-estradiol, DHEA-S, progesterone, testosterone,
and the thyroid hormones T3 and T4. The bone turnover markers osteocalcin
and beta-crosslaps (β-CTX) were validated using an ECLIA system.
In sports nutrition, the validated methods have potential applications in
monitoring vitamin D status and identifying alterations in the endocrine
system or bone metabolism. For example VAMS® were used within a
longitudinal study involving 45 athletes over a 10-week period during the
German winter months revealed a decrease in 25(OH)D concentration in VAMS® samples (41.4±22.4 vs. 25.9±10.5 ng/ml, p < 0.01) or to create
individual profiles for selected parameters, either on a one-time or regular
basis, to assess the risk of REDs in both females and males. Regarding
feasibility, 89% of the 90 athletes preferred VAMS® over venipuncture.
Pooled data indicated that 93% of n=360 self-collected VAMS® samples
were correctly collected by the athletes. In conclusion, VAMS® offers a
practical opportunity for athletes, scientists and practitioners to simplify
blood sample collection. The validation results showed high validity of the
analytical methods for accurate quantification and interpretation of values.
For vitamin D, VAMS® facilitates the early identification of deficient
25(OH)D concentrations, enabling individualized supplementation during
winter. For REDs, VAMS® supports regular hormone monitoring to
prevent health consequences and track the progress of REDs therapy.
Original languageEnglish
JournalInternational Journal of Sport Nutrition and Exercise Metabolism
Volume2026
Issue number36
Number of pages1
Publication statusPublished - 24.01.2026