Impact of knee joint loading on fragmentation of serum cartilage oligomeric matrix protein

Publikationen: Beitrag in FachzeitschriftZeitschriftenaufsätzeForschungBegutachtung

Standard

Impact of knee joint loading on fragmentation of serum cartilage oligomeric matrix protein. / Firner, Sara; Zaucke, Frank; Heilig, Juliane et al.

in: Journal of orthopaedic research : official publication of the Orthopaedic Research Society, Jahrgang 38, Nr. 8, 01.08.2020, S. 1710-1718.

Publikationen: Beitrag in FachzeitschriftZeitschriftenaufsätzeForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{bd9ca4437d084e90938dadd49cd343a0,
title = "Impact of knee joint loading on fragmentation of serum cartilage oligomeric matrix protein",
abstract = "The aim of the study was to examine the effect of mechanical knee joint loading on the fragmentation pattern of serum cartilage oligomeric matrix protein (COMP). Ten healthy men ran with knee orthoses that were passive or active (+30.9 N·m external flexion moments) on a treadmill (30 minute; v = 2.2 m/s). Lower-limb mechanics, serum COMP levels, and fragmentation patterns (baseline; 0, 0.5, 1, 2 hours postrunning) were analyzed. Running with active orthoses enhanced knee flexion moments, ankle dorsiflexion, and knee flexion angles (P < .05). There was an increase in serum COMP (+25%; pre: 8.9 ± 2.4 U/l; post: 10.7 ± 1.9 U/l, P = .001), COMP pentamer/tetramer (+88%; 1.88 ± 0.81, P = .007), trimer (+209%; 3.09 ± 2.65, P = .005), and monomer (+78%; 1.78 ± 0.85, P = .007) after running with passive orthoses and in serum COMP (+41%; pre: 8.5 ± 2.7 U/l; post: 11.3 ± 2.1 U/l, P < .001), COMP pentamer/tetramer (+57%; 1.57 ± 0.39, P = .007), trimer (+86%; 1.86 ± 0.47, P = .005), and monomer (+19%; 1.19 ± 0.34, P = .114) after running with active orthoses. Increased fragmentation might indicate COMP release from cartilage while running. Interestingly, 0.5 h up to 2 hours after running with passive orthoses, trimer (0.5 hour: 2.73 ± 3.40, P = .029; 2 hours: 2.33 ± 2.88, P = .037), and monomer (0.5 hour: 2.23 ± 2.33, P = .007; 1 hour: 2.55 ± 1.96, P = .012; 2 hours: 2.65 ± 2.50, P = .009) increased while after running with active orthoses, pentamer/tetramer (1 hour: 0.79 ± 0.28, P = .029), and trimer (1 hour: 0.63 ± 0.14, P = .005; 2 hours: 0.68 ± 0.34, P = .047) decreased. It seems that COMP degradation and clearance vary depending on joint loading characteristics.",
keywords = "COMP, cartilage, fragmentation pattern, mechanical joint loading, western blot",
author = "Sara Firner and Frank Zaucke and Juliane Heilig and {de Mar{\'e}es}, Markus and Steffen Willwacher and Gert-Peter Br{\"u}ggemann and Anja Niehoff",
note = "{\textcopyright} 2020 The Authors. Journal of Orthopaedic Research {\textregistered} published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.",
year = "2020",
month = aug,
day = "1",
doi = "10.1002/jor.24586",
language = "English",
volume = "38",
pages = "1710--1718",
journal = "Journal of orthopaedic research : official publication of the Orthopaedic Research Society",
issn = "1554-527X",
publisher = "John Wiley and Sons Inc.",
number = "8",

}

RIS

TY - JOUR

T1 - Impact of knee joint loading on fragmentation of serum cartilage oligomeric matrix protein

AU - Firner, Sara

AU - Zaucke, Frank

AU - Heilig, Juliane

AU - de Marées, Markus

AU - Willwacher, Steffen

AU - Brüggemann, Gert-Peter

AU - Niehoff, Anja

N1 - © 2020 The Authors. Journal of Orthopaedic Research ® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.

PY - 2020/8/1

Y1 - 2020/8/1

N2 - The aim of the study was to examine the effect of mechanical knee joint loading on the fragmentation pattern of serum cartilage oligomeric matrix protein (COMP). Ten healthy men ran with knee orthoses that were passive or active (+30.9 N·m external flexion moments) on a treadmill (30 minute; v = 2.2 m/s). Lower-limb mechanics, serum COMP levels, and fragmentation patterns (baseline; 0, 0.5, 1, 2 hours postrunning) were analyzed. Running with active orthoses enhanced knee flexion moments, ankle dorsiflexion, and knee flexion angles (P < .05). There was an increase in serum COMP (+25%; pre: 8.9 ± 2.4 U/l; post: 10.7 ± 1.9 U/l, P = .001), COMP pentamer/tetramer (+88%; 1.88 ± 0.81, P = .007), trimer (+209%; 3.09 ± 2.65, P = .005), and monomer (+78%; 1.78 ± 0.85, P = .007) after running with passive orthoses and in serum COMP (+41%; pre: 8.5 ± 2.7 U/l; post: 11.3 ± 2.1 U/l, P < .001), COMP pentamer/tetramer (+57%; 1.57 ± 0.39, P = .007), trimer (+86%; 1.86 ± 0.47, P = .005), and monomer (+19%; 1.19 ± 0.34, P = .114) after running with active orthoses. Increased fragmentation might indicate COMP release from cartilage while running. Interestingly, 0.5 h up to 2 hours after running with passive orthoses, trimer (0.5 hour: 2.73 ± 3.40, P = .029; 2 hours: 2.33 ± 2.88, P = .037), and monomer (0.5 hour: 2.23 ± 2.33, P = .007; 1 hour: 2.55 ± 1.96, P = .012; 2 hours: 2.65 ± 2.50, P = .009) increased while after running with active orthoses, pentamer/tetramer (1 hour: 0.79 ± 0.28, P = .029), and trimer (1 hour: 0.63 ± 0.14, P = .005; 2 hours: 0.68 ± 0.34, P = .047) decreased. It seems that COMP degradation and clearance vary depending on joint loading characteristics.

AB - The aim of the study was to examine the effect of mechanical knee joint loading on the fragmentation pattern of serum cartilage oligomeric matrix protein (COMP). Ten healthy men ran with knee orthoses that were passive or active (+30.9 N·m external flexion moments) on a treadmill (30 minute; v = 2.2 m/s). Lower-limb mechanics, serum COMP levels, and fragmentation patterns (baseline; 0, 0.5, 1, 2 hours postrunning) were analyzed. Running with active orthoses enhanced knee flexion moments, ankle dorsiflexion, and knee flexion angles (P < .05). There was an increase in serum COMP (+25%; pre: 8.9 ± 2.4 U/l; post: 10.7 ± 1.9 U/l, P = .001), COMP pentamer/tetramer (+88%; 1.88 ± 0.81, P = .007), trimer (+209%; 3.09 ± 2.65, P = .005), and monomer (+78%; 1.78 ± 0.85, P = .007) after running with passive orthoses and in serum COMP (+41%; pre: 8.5 ± 2.7 U/l; post: 11.3 ± 2.1 U/l, P < .001), COMP pentamer/tetramer (+57%; 1.57 ± 0.39, P = .007), trimer (+86%; 1.86 ± 0.47, P = .005), and monomer (+19%; 1.19 ± 0.34, P = .114) after running with active orthoses. Increased fragmentation might indicate COMP release from cartilage while running. Interestingly, 0.5 h up to 2 hours after running with passive orthoses, trimer (0.5 hour: 2.73 ± 3.40, P = .029; 2 hours: 2.33 ± 2.88, P = .037), and monomer (0.5 hour: 2.23 ± 2.33, P = .007; 1 hour: 2.55 ± 1.96, P = .012; 2 hours: 2.65 ± 2.50, P = .009) increased while after running with active orthoses, pentamer/tetramer (1 hour: 0.79 ± 0.28, P = .029), and trimer (1 hour: 0.63 ± 0.14, P = .005; 2 hours: 0.68 ± 0.34, P = .047) decreased. It seems that COMP degradation and clearance vary depending on joint loading characteristics.

KW - COMP

KW - cartilage

KW - fragmentation pattern

KW - mechanical joint loading

KW - western blot

UR - https://www.mendeley.com/catalogue/a24e790c-f886-34ba-95ed-12947d94d909/

U2 - 10.1002/jor.24586

DO - 10.1002/jor.24586

M3 - Journal articles

C2 - 31944379

VL - 38

SP - 1710

EP - 1718

JO - Journal of orthopaedic research : official publication of the Orthopaedic Research Society

JF - Journal of orthopaedic research : official publication of the Orthopaedic Research Society

SN - 1554-527X

SN - 0736-0266

IS - 8

ER -